Skip to content

vectorgrp/sil-kit-fmu-importer

Repository files navigation

SIL Kit FMU Importer

The SIL Kit FMU Importer is an extension for SIL Kit (downloadable on GitHub; documentation on github.io) that allows to import Functional Mockup Units (FMUs, see https://fmi-standard.org) as SIL Kit participants and run them together with other participants (which may be other FMUs or other SIL Kit participants).

The FMU Importer is designed as a headless tool that does not need any user interaction. Its behavior is configured by configuration files that are passed during launch.

Table of Contents

  1. Overview of FMI
  2. Setup
    1. Requirements
    2. Build Instructions
      1. FMU Importer
      2. vCDL Exporter
      3. Communication Interface Exporter
  3. Running the FMU Importer
  4. Data, Time, and Lifecycle Handling
    1. Variable Representation
    2. Time and Lifecycle Management
    3. Data Synchronization
  5. Integration in SIL Kit Setups With Complex Data Structures
    1. Structures in SIL Kit
    2. The Communication Interface Description
    3. Available Options in Communication Interface Description
    4. Optional Data Types
    5. Variable Naming Convention in FMI and the FMU Importer
  6. Configuring the FMU and the FMU Importer
    1. Configuration Outline
    2. Available Options in Configuration
      1. Include
      2. Parameters
      3. VariableMappings
      4. VariableMappings.Transformation
  7. Error Handling

Overview of FMI

The FMI (Functional Mockup Interface) standard defines "a ZIP archive and an application programming interface (API) to exchange dynamic models using a combination of XML files, binaries and C code: the Functional Mock-up Unit (FMU)" (see https://fmi-standard.org/docs/3.0/#_overview).

In other words, an FMU represents a simulation component with defined parameter, output, and input variables in addition to an interface that allows to set and get those variables, control the simulation state of the FMU, and let the internal simulation time progress (and thus process the input variables).

The interface is stimulated through an Importer - an external tool with the task to synchronize the input and output variables of FMUs and coordinate their simulation progress.

Relation between an FMU and the Importer

The SIL Kit FMU Importer has two roles

  • make an FMU accessible as part of a SIL Kit simulation
  • act as a distributed importer that uses SIL Kit's virtual time synchronization for time synchronization between FMUs and synchronize the input and output variables via publishers and subscribers.

Setup

The SIL Kit FMU Importer ships as prebuilt portable packages. This means that the FMU Importer requires an installed .NET 6 Runtime on the target machine. The package itself provides executables for Windows and Linux. The Linux distributables are tested on Ubuntu 22.04, but they should also run on other similar distributions.

Please refer to the section Build Instructions if you want to build the FMU Importer yourself.

Requirements

  • .NET 6
    • .NET's download site has guides on how to get .NET 6 for your OS
    • May also be installed as part of a Visual Studio (v17.2+ / 2022) installation
  • SIL Kit* (only needed to run the FMU Importer; not required for build step)
    • Package can be downloaded from GitHub (SIL Kit)
    • The FMU Importer was tested with SIL Kit 4.0.50 and prebuilt packages ship with this SIL Kit version
  • FMU Importer Source Code

Build Instructions

The FMU Importer comes with preconfigured projects. The following sections provide instructions which projects you may build and what they do. Manually built binaries of the projects usually build into the folder _build/crossplatform-x64-{Configuration}.


FMU Importer

To build the FMU Importer itself, open a terminal in the project's root directory (the one that contains FmuImporter.sln) and run the .NET build command

  • Windows: dotnet build ./FmuImporter/FmuImporter.csproj -c Debug --no-self-contained -r win-x64

  • Linux: dotnet build ./FmuImporter/FmuImporter.csproj -c Debug --no-self-contained -r linux-x64

This builds the FMU Importer with a Debug configuration (-c Debug) and the Importer will need an installed DotNet 6.0 (--no-self-contained).

You can find a separate section below on how to use the importer.


vCDL Exporter

This tool allows you to export the model descriptions of FMUs as a vCDL file that can be imported into CANoe. To build it, open a terminal in the VcdlExporter directory (the one that contains VcdlExporter.sln) and run the .NET build command

  • Windows: dotnet build ./VcdlExporter/VcdlExporter.csproj -c Debug --no-self-contained -r win-x64

  • Linux: dotnet build ./VcdlExporter/VcdlExporter.csproj -c Debug --no-self-contained -r linux-x64

Alternatively, you can open the solution file in Visual Studio and build the vCDL Exporter from there.

Note: The vCDL exporter is currently a tool for internal debugging purposes and does not have any quality assurance. You may encounter crashes while using it.

The vCDL exporter can either export a vCDL file based on an FMU or based on a communication interface description.

To export a vCDL based on an FMU, you can run the following command from the folder where your vCDL Exporter binary resides: VcdlExporter fmu --input-path <Path/To/FMU> --output-path <Path/To/Exported/vCDL>

Only FMU containers are supported (not already extracted FMUs).

To export a vCDL based on a communication interface description, you can run the following command from the folder where your vCDL Exporter binary resides: VcdlExporter communicationInterface --input-path <Path/To/Comm-Interface> --output-path <Path/To/Exported/vCDL> --interface-name Default

All provided paths must include the file's extensions (e.g., .vcdl, .fmu, .yaml).


Communication Interface Exporter

This tool allows you to export the model descriptions of FMUs as a communication interface description file that can be provided to the FMU Importer. The order it will give to the members of structures is arbitrary. The structure types are based on the variables' names following FMI's structured naming convention, and the members are assigned to the correct structures.

To build it, open a terminal in the CommInterfaceExporter directory (the one that contains CommInterfaceExporter.sln) and run the .NET build command

  • Windows: dotnet build ./CommInterfaceExporter/CommInterfaceExporter.csproj -c Debug --no-self-contained -r win-x64

  • Linux: dotnet build ./CommInterfaceExporter/CommInterfaceExporter.csproj -c Debug --no-self-contained -r linux-x64

Alternatively, you can open the solution file in Visual Studio and build the Communication Interface Exporter from there.

Note: The Communication Interface Exporter is currently a tool for internal debugging purposes and does not have any quality assurance. You may encounter crashes while using it.

To export a communication interface description you can run the following command from the folder where your Communication Interface Exporter binary resides: CommInterfaceExporter --input-path <Path/To/FMU> --output-path <Path/To/Exported/CommItf>

Only FMU containers are supported (not already extracted FMUs).


Running the FMU Importer

Please make sure that you have a running and reachable SIL Kit registry before starting the FMU Importer executable.

If you built the FMU Importer yourself, you may need to copy the SilKit.dll/libSilKit.so file from a SIL Kit release package (we recommend SIL Kit 4.0.50) to the root folder of your build directory (the same folder where FmuImporter[.exe] is located).

To run the FMU Importer, you need to run the following command from the directory your built execuable resides in:

FmuImporter [options]

Available options are:

Option Description
-f, --fmu-path <fmu-path> (REQUIRED) Set the path to the FMU file (.fmu). This is mandatory.
-s, --sil-kit-config-file <sil-kit-config-file> Set the path to the SIL Kit configuration file.
-c, --fmu-importer-config-file <config-file> Set the path to the FMU Importer configuration file.
-i, --fmu-importer-communication-interface-file <communication-interface-file> Set the path to the FMU Importer configuration file.
-p, --participant-name <participant-name> Set the name of the SIL Kit participant. [default: sil-kit-fmu-importer]
--time-sync-mode <synchronized | unsynchronized> Choose the time synchronization mode. [default: synchronized]
--version Show version information
-?, -h, --help Show help and usage information

After running the command, the FMU Importer will internally create a SIL Kit participant and connect to the SIL Kit registry configured in the SIL Kit configuration file. If no configuration was provided or if it did not specify a registry URI, the default URI silkit://localhost:8500 will be used. The FMU Importer uses the SIL Kit logger for its output. Therefore, you need to provide a SIL Kit configuration file that contains a Logging section to see any output provided by the FMU Importer. The FMU Importer prints most of its logs on the Info level, but in case an error occurs, there is one log message on the Error level that contains the error message and a log message on the Debug level that contains the error message including further information (such as a stack trace) to track the error's origin more easily.

Data, Time, and Lifecycle Handling

From an FMU's point of view, the FMU Importer acts as a master (FMI 2.0)/importer (FMI 3.0). As such, the Importer will handle the data exchange via SIL Kit, the time management, and the lifecycle of the FMU. The FMU Importer does not provide any numeric solvers or interpolation mechanisms. Therefore, it only supports FMUs that can run in co-simulation mode.

Variable Representation

The FMU Importer exposes an FMU's variables as DataPublisher and DataSubscriber services to other SIL Kit simulation participants. By default, the variable's name is used as the topic name by the SIL Kit service. The FMU Importer maps the different kinds of variable types as follows:

Variable Type Created Service
Input DataSubscriber
Independent DataPublisher
Output DataPublisher
Parameter DataPublisher
Structural parameter DataPublisher

It is also possible to change the default mapping. See Configuring the FMU Importer for details.

Time and Lifecycle Management

The FMU Importer uses the simulation step size provided by the FMU's model description as simulation step size for the FMU, if it is available. In case the simulation step size is not available, the FMU Importer requires users to provide the simulation step size via the FMU Importer configuration file. If neither the FMU nor the configuration file provide a step size, the FMU Importer will exit and show an error message.

The FMU Importer provides time synchronization modes that allows users to choose, how virtual time shall be handled by the FMU Importer:

  • Synchronized (default): The FMU Importer's simulation time will be synchronized with other SIL Kit participants through SIL Kit's virtual time synchronization. If active, it ensures that all data from previous points in virtual time were received before processing the next simulation step. An FMU Importer that uses virtual time synchronization will execute the FMU's simulation steps as soon as the SIL Kit component signals that a simulation step may be performed. In addition, the FMU Importer coordinates its SIL Kit lifecycle with other SIL Kit participants. This means that the FMU Importer will first wait until all required participants have joined the SIL Kit simulation and then coordinates the lifecycle state with them. For details about SIL Kit's virtual time synchronization, refer to the SIL Kit Documentation. Further, if any of the required participants stops the simulation, all other participants, including the FMU Importer, will stop as well.

    Please make sure to start a sil-kit-system-controller (part of SIL Kit) that comprises the FMU Importer's participant name as well as all other required participants.

  • Unsynchronized: If the FMU Importer does not use virtual time synchronization, the simulation step execution will be artificially slowed down to to match the system's wall clock. For example, a one second simulation step would also take approximately one second in real time. It is important to note that the FMU Importer is not designed as a real-time application and cannot guarantee that the simulation steps will always have a perfect alignment with the real time, but it will stay as close as possible in the long run. In case it is not possible to execute the simulation step in time, the simulation will be executed as fast as possible. As an unsynchronized SIL Kit participant, FMU Importer receives its SIL Kit data without a timestamp and therefore schedules all messages to be provided to the FMU in the next simulation step (see below for details).

The time synchronization mode only affects how the FMU Importer interacts with SIL Kit, but it does not affect how the FMU Importer interacts with the FMU.

Data Synchronization

As mentioned in Variable Representation, input variables with the same name as other FMUs' output variables are connected and therefore receive their data.

The general procedure to synchronize the data between SIL Kit and the FMU is similar in synchronized and unsynchronized time synchronization mode (see Time and Lifecycle Management):

  1. Once SIL Kit grants the execution of the next simulation step, the FMU Importer provides all updated variable values to the FMU. When receiving data for a specific variable more than once before a simulation time step is executed, the last received value is used ("last-is-best").
  2. The simulation step of the FMU is executed.
  3. All output variables are read from the FMU and published via SIL Kit.

(Structural) parameters are only published at the beginning of a simulation (t=0), because they are not meant to change after the simulation started.

Sequence of a synchronized simulation step

Synchronization between an FMU and the Importer (synchronized)

Sequence of an unsynchronized simulation step

Synchronization between an FMU and the Importer (unsynchronized)

Integration in SIL Kit Setups With Complex Data Structures

In FMI, a variable's data type is limited to a scalar data type or an array thereof. However, SIL Kit's (de-)serialization classes do not have this restriction, and they may aggregate data in complex arrangements (structures). The following subsections explain how variables can be aggregated to structures in SIL Kit.

Structures in SIL Kit

The SIL Kit serialization classes allow to (de)serialize structured data. Structures may contain simple data types, enumerations, and other structures. Further, structure members can be optional (see Optional Data Types). Such members may not have a payload and are therefore "skipped" when processing a structure. The order and the data type of structure members are important to serialize and deserialize structures correctly and must therefore match between all SIL Kit participants.

The Communication Interface Description

The communication interface description defines the FMU Importer's communication interface toward other SIL Kit participants. It is described via a YAML file that can be provided via the command line interface of the FMU Importer (see Running the FMU Importer). Providing a communication interface description file is mandatory if structures are used, because it defines the order in which structure members are serialized.

    Version: 1

    EnumDefinitions:
    - ...

    StructDefinitions:
    - ...

    Publishers:
    - ...

    Subscribers:
    - ...

Available Options in Communication Interface Description

Name Type Description
Version Integer The version of the config format (mandatory).
EnumDefinitions Array<Object> Used to define enumerations and their items.
StructDefinitions Array<Object> Used to define structures.
Publishers Array<Object> Used to declare publisher services. This could be a scalar (including enums), list, or structure.
Subscribers Array<Object> Used to declare subscriber services. This could be a scalar (including enums), list, or structure.

Enumeration Definitions

Name Type Description
Name String Name of the enumeration definition.
IndexType String Type of the items' values. Defaults to Int64.
Items Array<Object> List of items that belong to the enumeration.

Each element of the Item list is of the form Name : Value.

Example:

EnumDefinitions:
  - Name: EnumSample
    Items:
      - "FirstEnumItem" : 1
      - "SecondEnumItem" : 7

Structure Definitions

Name Type Description
Name String Name of the structure definition.
Members Array<Object> List of members that belong to the structure.

Each element of the Members list must be in the form Name : Type where Type is a Supported Data Type, or a structure / enumeration defined in this file. Example:

StructDefinitions:
  - Name: StructSample
    Members:
      - Member1: int
      - Member2: double
      - Member3: EnumSample # reference to the enum defined in the example above

Publishers and Subscribers

Publishers and Subscribers are lists of Name : Type elements, identical to struct members. See Supported Data Types for a list of valid types. Example:

Publishers:
  - PubInt : Int
  - PubDouble : double
  - PubEnum : EnumSample
  - PubStruct : StructSample
  
Subscribers:
  - SubInt : Int
  - SubDouble : double
  - SubEnum : EnumSample
  - SubStruct : StructSample

Optional Data Types

In SIL Kit, variables (including structures) and structure members may be optional. Optional members provide information if their payload is available. Optional and non-optional data types are not compatible. In the configuration and the communication interface description, an optional data type is indicated by adding a question mark at the end of the type description. For example, a communication interface description may specify the following publishers:

Publishers:
   NonOptionalIntArray : List<Int32> #non-optional list of 32-bit integers
   OptionalIntArray : List<Int32>? #Optional list of non-optional 32-bit integers

The FMU Importer does not support optional data types within a list, since in FMI 3.0, arrays must be provided without missing entries. However, lists themselves may be optional (as shown in the example). Optional data types can be declared in the communication interface description and in the FMU Importer configuration file.

Note: Variables must have the same type in the FMU and comm. interface description.
If the types deviate, an explicit variables transformation must be defined via the FMU Importer configuration file.

Variable Naming Convention in FMI and the FMU Importer

With a few exceptions (e.g., string, binary), the FMI standard does not define any non-scalar data types. To indicate, that a group of variables (or other groups) belongs together, the FMI standard defines a variable naming convention. Essentially, a variable's name is separated through periods (.) to indicate its structure. For example, the structure of the three variables

gps.timecode
gps.position.latitude
gps.position.longitude

corresponds to the following structure:

gps
  timecode
  position
    latitude
    longitude

More details about FMI's naming convention can be found in the FMI standard (link to corresponding section in FMI 3.0).

If the FMU defines its naming convention to be 'structured', the FMU Importer uses it to automatically map FMU variables to SIL Kit structures defined in the Communication Interface Description. If an FMU does not explicitly use the structured naming convention, users can activate the detection of the naming convention by setting AlwaysUseStructuredNamingConvention in the FMU Importer configuration file to true (see Available Options in Configuration).

Note: It is possible to manually 'map' a variable, which is not named like a structure member, by assigning it a topic name that corresponds to the name it should have based on the structured naming convention.


Configuring the FMU and the FMU Importer

The FMU Importer can be optionally provided with a configuration file that affects, how the FMU Importer synchronizes data and time between the FMU and a SIL Kit simulation. Further, it allows to override the default values of parameter variables.

Configuration Outline

The configuration file is expected to be a valid YAML file with the following outline:

    Version: 2

    Include:
    - ...

    Parameters:
    - ...

    VariableMappings:
    - ...

    AlwaysUseStructuredNamingConvention: False

    IgnoreUnmappedVariables: False

    StepSize: 1000000

    Namespace: MyNamespace

    Instance: MyInstanceName

To help write this file, you may use the schema named FmuImporterConfiguration.schema.json in the root directory of the release package. It depends on your code editor if it supports YAML schemas and how they can be used. For instance, if you use Visual Studio Code with the Red Hat YAML extension, you can use the schema by adding the following first line to your configuration file:

# yaml-language-server: $schema=</path/to/FmuImporter>/FmuImporterConfiguration.schema.json

Available Options in Configuration

Name Type Description
Version Integer The version of the config format (mandatory).
Include Array<String> Used to include contents of other valid FMU Importer configuration files.
Parameters Array<Object> Used to override default values of parameters.
VariableMappings Array<Object> Used to modify how a variable is represented in a SIL Kit simulation.
AlwaysUseStructuredNamingConvention Boolean Force usage of variable naming convention for automatic structure mapping (see Variable Naming Convention in FMI and the FMU Importer).
IgnoreUnmappedVariables Boolean Set to true to prevent synchronization of variables that are not listed in VariableMappings (including parameters).
StepSize Integer Simulation step size in ns. Overrides step size provided by FMU (if available).
Namespace String Namespace for all SIL Kit publishers and subscribers (only used for disambiguation - do not use if not necessary).
Instance String Instance name for all SIL Kit publishers and subscribers (only used for disambiguation - do not use if not necessary).

The options Namespace and Instance help to disambiguate if multiple SIL Kit participants provide data with the same topic name. Only Publishers / Subscribers with the same instance name and namespace will exchange data. If the options are not set, all data will be received, and sent data will not be discernible.

These options may negatively impact the performance of the SIL Kit simulation. If possible, disambiguation should be done by renaming the topic names via transformations

Include

Used to include contents of other valid FMU Importer configuration files. Imported configuration files are evaluated before local definitions (e.g., parameters or variable mappings) are applied. Local definitions take precedence over imported definitions. In case of circular imports, a file will only be imported the first time it is encountered.

Syntax:

Include:
  - <path/to/fmu-importer-config>
  - ...

The paths to the included files can either absolute or relative to the including configuration file.

Parameters

Used to override default values of parameters. Each entry of the list must have the following attributes:

Name Type Description
VariableName String Name of the variable in the model description.
Value Object Value of the parameter. Type must match the definition in the model description.

The Value attribute may be one of the following:

  • A string (with single (') or double (") quotes) even if the content of the string is a numeric value;
  • A numeric value (example: 42, 3.14). If it's not representable by an integer type of size 64 bits or a double-precision floating point due to overflow, it'll be considered a string;
  • A list of the above (lists nesting is not supported).

If the VariableName designates a variable whose type is an enumeration, integer values are interpreted as the the enumerator's underlying value. If it is a string, it is interpreted as an enumerator's name and the value is taken from the Model Description.

In the case where the VariableName designates a variable whose type is a multi-dimensional array, the Value attribute is the flattened array which will be used to initialise the variable.

Syntax:

Parameters:
  - VariableName: <name-in-model-description>
    Value: <new-start-value>
  - VariableName: <enum-typed-variable-name-in-model-description>
    Value: "<name-of-enumerator-used-as-start-value>"
  - VariableName: <array-name-in-model-description>
    Value:
      - <first-item-of-the-start-value>
      - <second-item-of-the-start-value>
      - ...
  - ...

VariableMappings

Used to modify how a variable is represented in a SIL Kit simulation. The following properties of a variable can be modified:

Name Type Description
VariableName String Name of the variable in the model description (mandatory).
TopicName String The topic under which the publisher / subscriber that corresponds to the variable sends / receives the data. This means that input and output variables with the same topic name are connected.
Transformation Object Allows to add a linear transformation (factor and offset) and a typecast to the data before it is serialized by SIL Kit.

In the example below, there are two FMUs (FMU1 and FMU2) with variables that should be connected. However, they need to be reconfigured, because they do not have the same name. After applying configurations with the shown excerpts to their FMU Importers, the variables are connected.

Relation between an FMU and the Importer

VariableMappings.Transformation

In addition to the optional transformation that is part of a variable's unit, the FMU Importer allows to additional linear transformation as well as a type cast for floating point numbers and integers. If a linear transformation is applied to an integer, the result will be type casted from the resulting floating point number to the original integer type.

The point in time when the transformations are applied depends on the variable type:

  • Output variables: The linear transformation is applied after the UnitDefinition's transformation. The result is then cast to the target transmission type, serialized, and sent via the variable's corresponding SIL Kit DataPublisher.
  • Input variables: Once received by SIL Kit's DataSubscriber, the data is cast from the provided transmission type to the variable's data type. Then, the linear transformation is applied. At last, the FMU's unit transformation is applied.

The following properties of a variable can be modified:

Name Type Description
Factor Double First order part of the linear transformation. Applied before the offset.
Offset Double Constant offset of the linear transformation. Applied after the factor.
TransmissionType String Data encoding in SIL Kit. If necessary, the data is converted between the SIL Kit and the FMU components. See Supported Data Types for details
ReverseTransform Boolean Allows to reverse transformation if original factor and offset are known.

Syntax:

VariableMapping:
  - VariableName: <name-in-model-description>
    TopicName: <topic-name-in-sil-kit>
    Transformation: 
      Factor: <factor-of-linear-transform>
      Offset: <offset-of-linear-transform>
      TransmissionType: <see Supported Data Types below>
      ReverseTransform: {true|false}
  - ...

Supported Data Types

The FMU Importer supports the data type notation of FMI 2.0, 3.0, and their corresponding C# built-in data types.

FMI 3.0 FMI 2.0 C# type IsConvertible Description
Float32 - float Floating point number 32 with bits.
Float64 Real double Floating point number 64 with bits.
Int8 - sbyte Signed integer with 8 bits.
Int16 - short Signed integer with 16 bits.
Int32 Integer int Signed integer with 32 bits.
Int64 - long Signed integer with 64 bits.
UInt8 - byte Unsigned integer with 8 bits.
UInt16 - ushort Unsigned integer with 16 bits.
UInt32 - uint Unsigned integer with 32 bits.
UInt64 - ulong Unsigned integer with 64 bits.
Boolean Boolean bool Boolean with the values true or false (serialized as 8 bit)
String String string Concatenation of characters. Internally serialized as a list of bytes.
Binary - byte[] byte array or arbitrary length. Internally serialized as a list of bytes.

Notes:

  • All built-in data types are case-independent.
  • Enumerators are also supported.
  • Convertible data types can be converted into each other (as good as possible). Enumerators are not convertible.
  • In FMI 3.0, variables may also be (multi-dimensional) arrays. These are declared as lists in the FMU Importer (e.g., List<Double>).
  • Non-convertible data types cannot be used in type transformations.

Note: Currently, the FMU Importer does not support nested lists. Therefore, multi-dimensional FMI arrays are handled as their flattened counterparts as defined in the FMI 3.0 standard. This information is primarily important for other SIL Kit applications that want to exchange array data with the FMU Importer.

Members of structures that are not always available when the structure is distributed must be declared to be optional. This is done by appending a question mark (?) at the end of the data type.

The FMU Importer will never skip optional data when distributing structures. However, it is still important to declare the structure's data types correctly, as this impacts the serialization of the structure.


Error Handling

If the FMU Importer detects an issue, it will generally exit after terminating the FMU and stopping its SIL Kit lifecycle.

  • The error message is logged on an Error log level.
  • A more extensive error description is logged on the Debug log level. This includes a stack trace if the error originated from an exception.

If the FMU Importer exited without any issues, the exit code will be 0. All other exit codes set by the FMU Importer have four digits, of which the first digit indicates the component that reported the error:

  • 1-49: The error originated in the FMU Importer itself
  • 50-99: The error originated in the FMI binding
  • 100+: The error originated in the SIL Kit binding

The following table lists the meaning of the current exit codes:

Code Origin Description
0 FMU Importer The application terminated successfuly
1 FMU Importer Error during initialization
2 FMU Importer Error during simulation
3 FMU Importer Error during FMU's simulation step execution
4 FMU Importer Error during user callback execution
5 FMU Importer One of the required or provided files was not found
49 FMU Importer Encountered an unknown or unspecified error
51 FMI Binding Failed to load a library, most likely the FMU's .dll or .so file
52 FMI Binding Failed to read the FMU's model description file
53 FMI Binding FMU failed to terminate
54 FMI Binding FMU failed due to call that return with 'discard' status code
55 FMI Binding FMU failed due to call that return with 'error' status code
56 FMI Binding FMU failed due to call that return with 'fatal' status code
101 SIL Kit Binding Failed to log using SIL Kit's logger

About

C#-based FMU Importer for SIL Kit

Resources

License

Security policy

Stars

Watchers

Forks

Packages

No packages published

Contributors 3

  •  
  •  
  •  

Languages