Original file line number Diff line number Diff line change
@@ -0,0 +1,132 @@
{
"name": "(R) ESTAR HP FS (NG Furnace)",
"_description": "ENERGY STAR air source heat pump (w/ cold climates specs as applicable) fully replacing original gas furnace equipment",
"measure_type": "full service",
"market_entry_year": 2024,
"market_exit_year": null,
"climate_zone": "all",
"bldg_type": "all residential",
"structure_type": "all",
"panel_upgrade": ["Low EE upgrade", "Space/load control"],
"end_use": [
"heating",
"cooling"
],
"fuel_type": [
"natural gas",
"electricity"
],
"fuel_switch_to": "electricity",
"backup_fuel_fraction": null,
"technology": [
"furnace (NG)",
"central AC",
"room AC"
],
"htcl_tech_link": "ng furnace+cac&rac",
"tech_switch_to": "ASHP",
"energy_efficiency": {
"cold climates": {
"heating": 2.79,
"cooling": 4.69
},
"warm climates": {
"heating": 2.69,
"cooling": 4.69
}
},
"energy_efficiency_units": "COP",
"energy_efficiency_source": {
"notes": [
"Split system ducted (see Tables 2 (warm climates) and 3 (cold climates) in EPA source)",
"conversion from original standard: COP = SEER / 3.412, COP = HSPF / 3.412 (see EIA source)",
"split system conversion factors SEER2/SEER = 0.95, HSPF2/HSPF = 0.85 (see RESNET source)"
],
"source_data": [
{
"title": "ENERGY STAR Program Requirements Product Specification for Central Air Conditioner and Heat Pump Equipment Version 6.1",
"author": "U.S. Environmental Protection Agency",
"year": 2022,
"pages": 4,
"url": "https://www.energystar.gov/sites/default/files/asset/document/ENERGY%20STAR%20Version%206.1%20Central%20Air%20Conditioner%20and%20Heat%20Pump%20Final%20Specification%20%28Rev.%20January%20%202022%29.pdf"
},
{
"title": "Draft PDS:01, MINHERS Addendum 71, SEER2/HSPF2 Conversions",
"author": "RESNET",
"year": 2022,
"pages": 2,
"url": "https://www.resnet.us/about/standards/minhers/draft:pds:01:minhers:addendum:71:seer2:hspf2:conversions/"
},
{
"title": "Residential Demand Module of the National Energy Modeling System: Model Documentation 2014",
"author": "U.S. Energy Information Administration",
"year": 2014,
"pages": 17,
"url": "https://www.eia.gov/outlooks/aeo/nems/documentation/archive/pdf/m067(2014).pdf"
}
]
},
"installed_cost": {
"electricity": 0.0,
"natural gas": {
"new": 4380.0,
"existing": 13940.0
}
},
"cost_units": "2022$/unit",
"installed_cost_source": {
"notes": [
"Retail (new) and total installed (existing) cost for ENERGY STAR ASHPs in 2023",
"For existing buildings, added costs of $6300 are the average of the cost range for circuit breaker panel upgrade and home service upgrade costs in the NV5 report",
"a new circuit cost of 700 $2022 using the upper bound (assuming a high amperage 240V circuit is required for the HVAC system) from the NV5 report."
],
"source_data": [
{
"title": "Updated Buildings Sector Appliance and Equipment Costs and Efficiencies",
"author": "U.S. Energy Information Administration",
"year": 2023,
"pages": 39,
"url": "https://www.eia.gov/analysis/studies/buildings/equipcosts/pdf/full.pdf"
},
{
"title": "Service Upgrades for Electrification Retrofits Study Final Report",
"author": "NV5 and Redwood Energy",
"year": 2022,
"pages": 33,
"url": "https://pda.energydataweb.com/api/view/2635/Service%20Upgrades%20for%20Electrification%20Retrofits%20Study%20FINAL.pdf"
}
]
},
"product_lifetime": 15.0,
"product_lifetime_units": "years",
"product_lifetime_source": {
"notes": "Average of the ENERGY STAR range",
"source_data": {
"title": "Updated Buildings Sector Appliance and Equipment Costs and Efficiencies",
"author": "U.S. Energy Information Administration",
"year": 2023,
"pages": 39,
"url": "https://www.eia.gov/analysis/studies/buildings/equipcosts/pdf/full.pdf"
}
},
"market_scaling_fractions": {
"heating": 0.9,
"cooling": 0.49
},
"market_scaling_fractions_source": {
"notes": "Heating multiple of 90% was determined as proportion of total homes with gas heating that have both cooling and heating systems (8,624 homes out of 9,595 homes with gas heating). Cooling multiple of 49% was determined as a proportion of total homes with a cooling system (16,171 homes) where there is heating via natural gas other than steam/hot water (7,845 homes).",
"source_data": {
"title": "RECS 2020 Microdata",
"author": "U.S. Energy Information Administration",
"year": 2023,
"pages": null,
"url": "https://www.eia.gov/consumption/residential/data/2020/index.php?view=microdata"
}
},
"_updated_by": {
"name": "Jared Langevin",
"organization": "LBNL",
"email": "[email protected]",
"timestamp": "2024-06-11 13:55:11"
}
}
Original file line number Diff line number Diff line change
@@ -0,0 +1,132 @@
{
"name": "(R) ESTAR HP FS (NG Furnace)",
"_description": "ENERGY STAR air source heat pump (w/ cold climates specs as applicable) fully replacing original gas furnace equipment",
"measure_type": "full service",
"market_entry_year": 2024,
"market_exit_year": null,
"climate_zone": "all",
"bldg_type": "all residential",
"structure_type": "all",
"panel_upgrade": ["Low EE upgrade", "No panel management"],
"end_use": [
"heating",
"cooling"
],
"fuel_type": [
"natural gas",
"electricity"
],
"fuel_switch_to": "electricity",
"backup_fuel_fraction": null,
"technology": [
"furnace (NG)",
"central AC",
"room AC"
],
"htcl_tech_link": "ng furnace+cac&rac",
"tech_switch_to": "ASHP",
"energy_efficiency": {
"cold climates": {
"heating": 2.79,
"cooling": 4.69
},
"warm climates": {
"heating": 2.69,
"cooling": 4.69
}
},
"energy_efficiency_units": "COP",
"energy_efficiency_source": {
"notes": [
"Split system ducted (see Tables 2 (warm climates) and 3 (cold climates) in EPA source)",
"conversion from original standard: COP = SEER / 3.412, COP = HSPF / 3.412 (see EIA source)",
"split system conversion factors SEER2/SEER = 0.95, HSPF2/HSPF = 0.85 (see RESNET source)"
],
"source_data": [
{
"title": "ENERGY STAR Program Requirements Product Specification for Central Air Conditioner and Heat Pump Equipment Version 6.1",
"author": "U.S. Environmental Protection Agency",
"year": 2022,
"pages": 4,
"url": "https://www.energystar.gov/sites/default/files/asset/document/ENERGY%20STAR%20Version%206.1%20Central%20Air%20Conditioner%20and%20Heat%20Pump%20Final%20Specification%20%28Rev.%20January%20%202022%29.pdf"
},
{
"title": "Draft PDS:01, MINHERS Addendum 71, SEER2/HSPF2 Conversions",
"author": "RESNET",
"year": 2022,
"pages": 2,
"url": "https://www.resnet.us/about/standards/minhers/draft:pds:01:minhers:addendum:71:seer2:hspf2:conversions/"
},
{
"title": "Residential Demand Module of the National Energy Modeling System: Model Documentation 2014",
"author": "U.S. Energy Information Administration",
"year": 2014,
"pages": 17,
"url": "https://www.eia.gov/outlooks/aeo/nems/documentation/archive/pdf/m067(2014).pdf"
}
]
},
"installed_cost": {
"electricity": 0.0,
"natural gas": {
"new": 4380.0,
"existing": 13940.0
}
},
"cost_units": "2022$/unit",
"installed_cost_source": {
"notes": [
"Retail (new) and total installed (existing) cost for ENERGY STAR ASHPs in 2023",
"For existing buildings, added costs of $6300 are the average of the cost range for circuit breaker panel upgrade and home service upgrade costs in the NV5 report",
"a new circuit cost of 700 $2022 using the upper bound (assuming a high amperage 240V circuit is required for the HVAC system) from the NV5 report."
],
"source_data": [
{
"title": "Updated Buildings Sector Appliance and Equipment Costs and Efficiencies",
"author": "U.S. Energy Information Administration",
"year": 2023,
"pages": 39,
"url": "https://www.eia.gov/analysis/studies/buildings/equipcosts/pdf/full.pdf"
},
{
"title": "Service Upgrades for Electrification Retrofits Study Final Report",
"author": "NV5 and Redwood Energy",
"year": 2022,
"pages": 33,
"url": "https://pda.energydataweb.com/api/view/2635/Service%20Upgrades%20for%20Electrification%20Retrofits%20Study%20FINAL.pdf"
}
]
},
"product_lifetime": 15.0,
"product_lifetime_units": "years",
"product_lifetime_source": {
"notes": "Average of the ENERGY STAR range",
"source_data": {
"title": "Updated Buildings Sector Appliance and Equipment Costs and Efficiencies",
"author": "U.S. Energy Information Administration",
"year": 2023,
"pages": 39,
"url": "https://www.eia.gov/analysis/studies/buildings/equipcosts/pdf/full.pdf"
}
},
"market_scaling_fractions": {
"heating": 0.9,
"cooling": 0.49
},
"market_scaling_fractions_source": {
"notes": "Heating multiple of 90% was determined as proportion of total homes with gas heating that have both cooling and heating systems (8,624 homes out of 9,595 homes with gas heating). Cooling multiple of 49% was determined as a proportion of total homes with a cooling system (16,171 homes) where there is heating via natural gas other than steam/hot water (7,845 homes).",
"source_data": {
"title": "RECS 2020 Microdata",
"author": "U.S. Energy Information Administration",
"year": 2023,
"pages": null,
"url": "https://www.eia.gov/consumption/residential/data/2020/index.php?view=microdata"
}
},
"_updated_by": {
"name": "Jared Langevin",
"organization": "LBNL",
"email": "[email protected]",
"timestamp": "2024-06-11 13:55:11"
}
}
Loading