Skip to content

Releases: rmorgan001/GSServer

v1.0.8.6 Beta

03 Oct 16:22
Compare
Choose a tag to compare
v1.0.8.6 Beta Pre-release
Pre-release

v1.0.8.6 Beta

  1. AltAz changes for cancellation of asynchronous tasks
  2. Double click RA coordinates to show in degrees vs hours
  3. Pulse is now async with cancelation token
  4. Pulse now captures current speed and return to it after the pulse
  5. Park Dialog On option added
  6. Home Dialog On option added
  7. GPS com port fix
  8. Miscellaneous minor updates

v1.0.8.5 Beta

16 Aug 18:38
Compare
Choose a tag to compare
v1.0.8.5 Beta Pre-release
Pre-release

v1.0.8.5 Beta

  1. Updated Language files
  2. Added Horizon limits for GEM mounts
  3. Other minor updates and Alt/Az fixes
  • Apply Sidereal tracking rate to manual slew when tracking is active
  • Correct “bounce” in axes position when manual slewing is finished
  • Correct “stop/start” motion when manual slewing when tracking is active

v1.0.8.1 Beta

12 Apr 04:23
f8fa624
Compare
Choose a tag to compare
v1.0.8.1 Beta Pre-release
Pre-release

v1.0.8.1 Beta

  1. Added support Alt/Az mounts
Swap the Flip SOP button for a Flip Az Direction button to move the mount to the alternative position when it’s been slewed past 180 degrees.
Swap the sideOfPier indicator in the bottom status bar to show which direction the mount is slewed from North in Alt Az mode.
Added an Alt Az GoTo dialogue which works the same as the existing Ra Dec GoTo dialogue. The user can swap between them on the main GUI with a mouse right click in the GoTo area – this works for Alt Az and Ra Dec modes
  1. Added key events for ASWD keys in the hand controller

v1.0.8.0 Beta

21 Mar 14:39
Compare
Choose a tag to compare
v1.0.8.0 Beta Pre-release
Pre-release

v1.0.8.0 Beta

  1. Updates added to support Alt/Az mounts
  2. Added PHD2 dithering to the Snap Tab
  3. Updates for German translation file

v1.0.7.8 Beta

22 Feb 15:57
Compare
Choose a tag to compare
v1.0.7.8 Beta Pre-release
Pre-release

v1.0.7.8 Beta

  1. Language Support added for German
  2. Logging folder is now configurable on the Options/Monitor screen
  3. New performance setting added to the 3D settings tab. Controls how often the Model is updated and is based on the Options/Interval setting and how often the mount is polled for positions.
  4. Manual updated to correct some PPEC information

v1.0.7.5 Beta

05 Jan 15:12
Compare
Choose a tag to compare
v1.0.7.5 Beta Pre-release
Pre-release

v1.0.7.5 Beta

  1. Support added for Alt/Az mounts
  2. GPS fix for com ports
  3. Warning threshold added for alignment settings
  4. Manual updated for Alignment and Focuser

v1.0.6.5

17 Nov 14:11
Compare
Choose a tag to compare

v1.0.6.5

  1. Correction to report the correct windows version in the log files
  2. Added 2 new API calls Get_j and CmdToMount
  3. Correction for simulator not plotting positions

v1.0.6.4 beta

09 Oct 21:15
Compare
Choose a tag to compare
v1.0.6.4 beta Pre-release
Pre-release

v1.0.6.4 beta

  1. Added a warning threshold setting to the alignment settings. This will allow the user to control the sensitivity of the warning trigger. Bigger the number the bigger the offset allowed before triggering the warning. The number selected (1-10) is used to multiply the maximum offset entered via syncs.
  2. Added a "Forced flip on next GoTo" option under the "Flip SOP" button. Use this on the next goto slew command for crossing the meridian and you want the mount to flip instead of taking the shorter route.
  3. Added new confirm dialogs for the Home and Park Buttons

v1.0.6.2 beta

01 Sep 13:09
Compare
Choose a tag to compare
v1.0.6.2 beta Pre-release
Pre-release

v1.0.6.2 beta

  1. Added missing files for the Alignment charting.
  2. Added extra verification for resetting the 3D camera model position
  3. Minor updates for Wifi
  4. Corrected Simulator using MoveAxis() commands from external apps

v1.0.6.1 beta

29 Jun 12:26
Compare
Choose a tag to compare
v1.0.6.1 beta Pre-release
Pre-release

v1.0.6.1 beta

  1. Added support for SW Wifi mounts and adapter. All users may have to reconfigure the com port used. First connect Windows to the SyncScan wifi then configure GSS in settings to find it.
  2. Modified Monitor and logs to better represent the areas in code.
  3. Modified the way axis positions are reported to the server and UI. Now implements INotifyPropertyChanged
  4. Correction for step calculations. Math to be applied equally for negative positions . Now uses Math Rounding instead of Math Floor or Ceiling.

Special Thanks to... Sebastian, Tom, Andrew, & Colm