Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

DM should ignore some bits while abstract command is executing #1046

Merged
merged 5 commits into from
Jul 23, 2024
Merged
Show file tree
Hide file tree
Changes from 2 commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
5 changes: 5 additions & 0 deletions debug_module.adoc
Original file line number Diff line number Diff line change
Expand Up @@ -369,6 +369,11 @@ of {dm-data0}) or hart (e.g. contents of a register modified by a Program Buffe
Before starting an abstract command, a debugger must ensure that {dmcontrol-haltreq}, {dmcontrol-resumereq}, and {dmcontrol-ackhavereset} are all 0.

While an abstract command is executing ({abstractcs-busy} in {dm-abstractcs} is high), a debugger must not change {hartsel}, and must not write 1 to {dmcontrol-haltreq}, {dmcontrol-resumereq}, {dmcontrol-ackhavereset}, {dmcontrol-setresethaltreq}, or {dmcontrol-clrresethaltreq}.
The exception to this rule is when the debugger writes 0 to
{dmcontrol-dmactive}. In that case {hartsel} may be written with a new value
(which the hardware should ignore).
The hardware should not rely on this debugger behavior, but enforce it by
ignoring writes to these bits while {abstractcs-busy} is high.
rtwfroody marked this conversation as resolved.
Show resolved Hide resolved

If an abstract command does not complete in the expected time and
appears to be hung, the debugger can try to reset the hart (using {dmcontrol-hartreset} or {dmcontrol-ndmreset}).
Expand Down
24 changes: 22 additions & 2 deletions xml/dm_registers.xml
Original file line number Diff line number Diff line change
Expand Up @@ -177,7 +177,8 @@ same project unless stated otherwise.
and at most 20. A debugger should discover `HARTSELLEN` by writing
all ones to {hartsel} (assuming the maximum size) and reading back the
value to see which bits were actually set. Debuggers must not change
{hartsel} while an abstract command is executing.
{hartsel} while an abstract command is executing. Hardware should enforce
this by ignoring changes to {hartsel} while {abstractcs-busy} is set.

[NOTE]
====
Expand Down Expand Up @@ -219,6 +220,9 @@ same project unless stated otherwise.
set.

Writes apply to the new value of {hartsel} and {dmcontrol-hasel}.

Writes to this bit should be ignored while an abstract command is
executing.
</field>
<field name="resumereq" bits="30" access="W1" reset="-">
Writing 1 causes the currently selected harts to resume once, if
Expand All @@ -228,6 +232,9 @@ same project unless stated otherwise.
{dmcontrol-resumereq} is ignored if {dmcontrol-haltreq} is set.

Writes apply to the new value of {hartsel} and {dmcontrol-hasel}.

Writes to this bit should be ignored while an abstract command is
executing.
</field>
<field name="hartreset" bits="29" access="WARL" reset="0">
This optional field writes the reset bit for all the currently
Expand All @@ -253,6 +260,9 @@ same project unless stated otherwise.
</value>

Writes apply to the new value of {hartsel} and {dmcontrol-hasel}.

Writes to this bit should be ignored while an abstract command is
executing.
</field>
<field name="ackunavail" bits="27" access="W1" reset="-">
<value v="0" name="nop">
Expand Down Expand Up @@ -315,12 +325,18 @@ same project unless stated otherwise.
Writes apply to the new value of {hartsel} and {dmcontrol-hasel}.

If {dmstatus-hasresethaltreq} is 0, this field is not implemented.

Writes to this bit should be ignored while an abstract command is
executing.
</field>
<field name="clrresethaltreq" bits="2" access="W1" reset="-">
This optional field clears the halt-on-reset request bit for all
currently selected harts.

Writes apply to the new value of {hartsel} and {dmcontrol-hasel}.

Writes to this bit should be ignored while an abstract command is
executing.
</field>
<!-- Fields that apply to the entire DM. -->
<field name="ndmreset" bits="1" access="R/W" reset="0">
Expand All @@ -340,13 +356,17 @@ same project unless stated otherwise.
state change has completed. Hardware may
take an arbitrarily long time to complete activation or deactivation and will
indicate completion by setting {dmcontrol-dmactive} to the requested value.
During this time, the DM may ignore any register writes.

<value v="0" name="inactive">
The module's state, including authentication mechanism,
takes its reset values (the {dmcontrol-dmactive} bit is the only bit which can
be written to something other than its reset value). Any accesses
to the module may fail. Specifically, {dmstatus-version} might not return
correct data.

When this value is written, the DM may ignore any other bits written
rtwfroody marked this conversation as resolved.
Show resolved Hide resolved
to {dmcontrol} in the same write.
</value>

<value v="1" name="active">
Expand All @@ -356,7 +376,7 @@ same project unless stated otherwise.
No other mechanism should exist that may result in resetting the
Debug Module after power up.

To place the Debug Module into a known state, a debugger may write 0 to {dmcontrol-dmactive},
To place the Debug Module into a known state, a debugger should write 0 to {dmcontrol-dmactive},
poll until {dmcontrol-dmactive} is observed 0, write 1 to {dmcontrol-dmactive}, and
poll until {dmcontrol-dmactive} is observed 1.

Expand Down
Loading