Skip to content

Commit

Permalink
Load data before trigger priority was ambiguous.
Browse files Browse the repository at this point in the history
  • Loading branch information
pdonahue-ventana authored and rtwfroody committed Mar 21, 2024
1 parent c26ba92 commit f8dad44
Showing 1 changed file with 2 additions and 2 deletions.
4 changes: 2 additions & 2 deletions Sdtrig.adoc
Original file line number Diff line number Diff line change
Expand Up @@ -118,7 +118,7 @@ Instruction address misaligned +
Environment call +
Environment break +
Load/Store/AMO address breakpoint
.>| mcontrol/mcontrol6 load/store address/data before
.>| mcontrol/mcontrol6 load/store address before, store data before
|| 4, 6 | Optionally: Load/Store/AMO address misaligned |
|| 13, 15, 21, 23, 5, 7 | During address translation for an explicit
memory access: First encountered page fault, guest-page fault, or access
Expand Down Expand Up @@ -370,4 +370,4 @@ trigger firing at a different time than is expected.
Attempts to access an unimplemented Trigger Module Register raise an illegal
instruction exception.

include::build/hwbp_registers.adoc[]
include::build/hwbp_registers.adoc[]

0 comments on commit f8dad44

Please sign in to comment.