Notifications
You must be signed in to change notification settings - Fork 791
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Speed-up dramatically proj.db build time.
Current proj.db build time is typically 50 to 60 seconds (and up to 7.5 hours on arm64 cross-compilation with full emulation!). Most of it is due to running consistency checks. Those checks actually only need to run once each timewhen we update the content of the database. When skipping them, the build time is cut to 3 seconds or so. So in data/CMakeLists.txt, let keep track of an expected md5sum resulting from the concatenation of the data/sql/*.sql files. When building proj.db, we check if the got and expected md5sum match. If they do build proj.db by inserting the consistency check triggers after having inserted data record. If there's a mismatch, do a one time build with the triggers inserted before the data records, check that proj.db builds fine with that, and if so, emit a CMake error message indicating to the user that they must update the PROJ_DB_SQL_EXPECTED_MD5 variable in data/CMakeLists.txt with the provided value. Next runs will go through the fast build path, until content is updated again.
- Loading branch information
Showing
9 changed files
with
257 additions
and
200 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
ANALYZE; | ||
|
||
VACUUM; |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,9 @@ | ||
|
||
CREATE TRIGGER conversion_method_check_insert_trigger_orthographic | ||
INSTEAD OF INSERT ON conversion | ||
BEGIN | ||
|
||
SELECT RAISE(ABORT, 'insert on conversion violates constraint: bad parameters for Orthographic') | ||
WHERE NEW.deprecated != 1 AND NEW.method_auth_name = 'EPSG' AND NEW.method_code = '9840' AND (NEW.method_name != 'Orthographic' OR NEW.param1_auth_name != 'EPSG' OR NEW.param1_code != '8801' OR NEW.param1_name != 'Latitude of natural origin' OR NEW.param1_value IS NULL OR NEW.param1_uom_auth_name IS NULL OR NEW.param1_uom_code IS NULL OR (SELECT type FROM unit_of_measure WHERE auth_name = NEW.param1_uom_auth_name AND code = NEW.param1_uom_code) != 'angle' OR NEW.param2_auth_name != 'EPSG' OR NEW.param2_code != '8802' OR NEW.param2_name != 'Longitude of natural origin' OR NEW.param2_value IS NULL OR NEW.param2_uom_auth_name IS NULL OR NEW.param2_uom_code IS NULL OR (SELECT type FROM unit_of_measure WHERE auth_name = NEW.param2_uom_auth_name AND code = NEW.param2_uom_code) != 'angle' OR NEW.param3_auth_name != 'EPSG' OR NEW.param3_code != '8806' OR NEW.param3_name != 'False easting' OR NEW.param3_value IS NULL OR NEW.param3_uom_auth_name IS NULL OR NEW.param3_uom_code IS NULL OR (SELECT type FROM unit_of_measure WHERE auth_name = NEW.param3_uom_auth_name AND code = NEW.param3_uom_code) != 'length' OR NEW.param4_auth_name != 'EPSG' OR NEW.param4_code != '8807' OR NEW.param4_name != 'False northing' OR NEW.param4_value IS NULL OR NEW.param4_uom_auth_name IS NULL OR NEW.param4_uom_code IS NULL OR (SELECT type FROM unit_of_measure WHERE auth_name = NEW.param4_uom_auth_name AND code = NEW.param4_uom_code) != 'length' OR NEW.param5_auth_name IS NOT NULL OR NEW.param5_code IS NOT NULL OR NEW.param5_name IS NOT NULL OR NEW.param5_value IS NOT NULL OR NEW.param5_uom_auth_name IS NOT NULL OR NEW.param5_uom_code IS NOT NULL OR NEW.param6_auth_name IS NOT NULL OR NEW.param6_code IS NOT NULL OR NEW.param6_name IS NOT NULL OR NEW.param6_value IS NOT NULL OR NEW.param6_uom_auth_name IS NOT NULL OR NEW.param6_uom_code IS NOT NULL OR NEW.param7_auth_name IS NOT NULL OR NEW.param7_code IS NOT NULL OR NEW.param7_name IS NOT NULL OR NEW.param7_value IS NOT NULL OR NEW.param7_uom_auth_name IS NOT NULL OR NEW.param7_uom_code IS NOT NULL); | ||
|
||
END; |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.