Shuttle doors never close after starting to close because the bolts are already down by the time it tries #29813

Open
DrSmugleaf opened this issue Jul 8, 2024 · 0 comments
Labels
Status: Untriaged Somebody go through and give this appropriate labels

Comments

@DrSmugleaf
Copy link
Member

Description

Have an open door with a dude in the way
Have the door's perform collision check set to false
Start FTL
Door starts closing
Door bolts
By the time it goes from Closing > Close SharedDoorSystem.OnBeforeDoorClosed cancels the close because the bolts are down