Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

MetricFamilyToOpenMetrics produces output that cannot be parsed #319

Open
fstab opened this issue Jul 25, 2021 · 1 comment
Open

MetricFamilyToOpenMetrics produces output that cannot be parsed #319

fstab opened this issue Jul 25, 2021 · 1 comment

Comments

@fstab
Copy link
Member

fstab commented Jul 25, 2021

I am debugging prometheus/jmx_exporter#621, and I found I can reproduce the root cause of the error with the following test in github.com/prometheus/common/expfmt:

package expfmt

import (
	"bytes"
	"strings"
	"testing"
)

func TestJvmClassesLoaded(t *testing.T) {
	in := `
# HELP jvm_classes_loaded The number of classes that are currently loaded in the JVM
# TYPE jvm_classes_loaded gauge
jvm_classes_loaded 6129.0
# HELP jvm_classes_loaded_total The total number of classes that have been loaded since the JVM has started execution
# TYPE jvm_classes_loaded_total counter
jvm_classes_loaded_total 6143.0
`
	metricFamilies, err := parser.TextToMetricFamilies(strings.NewReader(in))
	if err != nil {
		t.Error(err)
	}
	openMetricsOutput := bytes.NewBuffer(make([]byte, 0))
	for _, metricFamily := range metricFamilies {
		if _, err := MetricFamilyToOpenMetrics(openMetricsOutput, metricFamily); err != nil {
			t.Fatal(err)
		}
	}
	if _, err := FinalizeOpenMetrics(openMetricsOutput); err != nil {
		t.Fatal(err)
	}
	_, err = parser.TextToMetricFamilies(strings.NewReader(openMetricsOutput.String()))
	if err != nil {
		t.Error(err)
	}
}

It fails with

=== RUN   TestJvmClassesLoaded
    jvm_classes_loaded_test.go:33: text format parsing error in line 4: second HELP line for metric name "jvm_classes_loaded"
--- FAIL: TestJvmClassesLoaded (0.00s)
FAIL
FAIL    github.com/prometheus/common/expfmt     0.002s
FAIL

As the error message indicates, the reason is that the _total suffix is truncated in HELP and TYPE (as defined in #214), and the resulting "short name" conflicts with the name of the gauge.

Two full serialization steps are needed to trigger the error (OpenMetrics format -> Go objects -> OpenMetrics format -> Go objects), so this might seem like an issue that doesn't occur in practice. However, in prometheus/jmx_exporter#621 this happens because of the following setup:

jmx_exporter -> exporter_exporter -> Prometheus server

I'm not sure what to do about this. Should exporters prevent metrics from having the same "short name"?

@beorn7
Copy link
Member

beorn7 commented Jul 26, 2021

There is a similar issue over in client_golang: prometheus/client_golang#829

I have run into this use case often enough by now (seeing it in core Prometheus repos is just the tip of the iceberg) that I see it as a quite seriously breaking change introduced by OpenMetrics. Given that OpenMetrics tries to be "just what Prometheus has done so far and what has proven to work well", I can only encourage OpenMetrics to reconsider the behavior here.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment