Skip to content

Latest commit

 

History

History
32 lines (22 loc) · 1.63 KB

collector.thermalzone.md

File metadata and controls

32 lines (22 loc) · 1.63 KB

thermalzone collector

The thermalzone collector exposes metrics about system temps. Note that temperature is given in Kelvin

Metric name prefix thermalzone
Classes Win32_PerfRawData_Counters_ThermalZoneInformation
Enabled by default? No

Flags

None

Metrics

Name Description Type Labels
windows_thermalzone_percent_passive_limit % Passive Limit is the current limit this thermal zone is placing on the devices it controls. A limit of 100% indicates the devices are unconstrained. A limit of 0% indicates the devices are fully constrained. gauge None
windows_thermalzone_temperature_celsius Temperature of the thermal zone, in degrees Celsius. gauge None
windows_thermalzone_throttle_reasons Throttle Reasons indicate reasons why the thermal zone is limiting performance of the devices it controls. 0x0 - The zone is not throttled. 0x1 - The zone is throttled for thermal reasons. 0x2 - The zone is throttled to limit electrical current. gauge None

Throttle reasons source

Example metric

This collector does not yet have explained examples, we would appreciate your help adding them!

Useful queries

This collector does not yet have any useful queries added, we would appreciate your help adding them!

Alerting examples

This collector does not yet have alerting examples, we would appreciate your help adding them!