New PW firmware seems to break vitals - 23.44.0 #57
Comments
Thanks for opening this @ganeshtheju . If you can, please try some of these:
|
raw vitals don't work either: (both from pypowerwall, or directly trying to hit the teg vitals endpoint [returns a 404]) `Device Version: Device Vitals: pw.poll: As far as i can tell, the pw charge/capacity/temps/reserve setpoint and alerts arent working, but everything else (meters etc) are working. |
It appears that there is atleast one other pypowerwall user who had gotten this update and is no longer getting vitals: |
It looks like the teg webgui gets its reserve values from /api/operation; even logged in as an installer I can't find any endpoints with the pod values or the alerts. |
@dscoffe39 Thanks! If the /api/device/vitals API is no longer available (404) in this firmware release, that would explain why the other functions (PW charge, etc) are also missing. Are you still seeing the power flow animation when you log in to the Gateway portal or use the Powerwall Dashboard? |
@jasonacox Yes the power flow still shows up on the teg website and the pypowerwall proxy root |
Thanks, @dscoffe39 Unfortunately, I don't think there is a lot we are going to be able to do to recover the device vitals API or data after this Firmware upgrade. I think this is the first of many changes we will see. As you can see from the TEG portal UI and on the new Powerwall 3, it appears that the direction from Tesla is toward the "Tesla Pros" app to make it easier to install and manage for the majority of their customers. For data nerds like us, we are going to need to pivot and figure out new ways to get what we want. I'm hopeful there will be some easy/good way to accomplish that over next few months. Request/Notice to the community:
I know changes like this can be frustrating, but I also acknowledge that the Tesla teams need to optimize for the entire customer base and not just us. Still, I'm hopeful that we will be able to figure out ways to bridge most of what we enjoy with the rich data from our Powerwalls, even if we have some work to do to get there. |
@jasonacox Thanks for looking into this; I was afraid that eventually we would see changes like this; I think for full metrics we would need to tap into the can bus between the gw and the pws. Using the tesla pro app its possible to see at-least the individual line voltages and frequencies of the grid/pws/home, but in all my digging there doesn't seem to be an exposed api to do it from the customer login; I'm not versed well enough to do packet captures and decode them (assuming its possible as they should be tls encrypted) or to reverse engineer the telsa pros app to see where its making the calls to retreve that data. |
The CAN bus idea is interesting. Has anyone tried that? On the Tesla Pros app reverse engineering, there is a start here jasonacox/Powerwall-Dashboard#392 but the downside is that it seems to require being on the TEG WiFi access point which, in my experience, is a bit finicky and prone to timeouts. I'm still hopeful that there will be a simple and robust way (introduced or discovered) to get the API data we want. |
Discussion here as well: jasonacox/Powerwall-Dashboard#402 |
Good luck team, hopefully the brain trust will figure out the proper way forward to keep our system data that we entitled to :) |
The latest pypowerwall release, v0.7.3, adds the ability to use the Tesla Owners API (via TeslaPy) to pull basic information and some extended information (e.g. firmware version, Powerwall full charge capacity, etc.). This could be helpful for Powerwall 3 (and Solar only) owners that do not have local API access. For those with local access, the release also adds aggregate Powerwall See release notes starting with https://github.com/jasonacox/pypowerwall/releases/tag/v0.7.1. This doesn't restore the rich data set in the vitals API but it does provide some. We continue to be hopeful that we will see an opportunity to restore more of the vitals data set for those that have lost it. |
@dscoffe39 and others with 23.44.0 - @BJReplay posted a reference to vloschiavo/powerwall2#55 in the Powerwall-Dashboard discussion related to this. Someone mentions getting vital details using a different authentication method. Right now pypowerwall is using AuthCookie and UserRecord tokens in the header once login (user supplied user/pass) is performed via https://10.0.1.28/api/login/Basic. You can see it cache those in the {
"email": "[email protected]",
"firstname": "Tesla",
"lastname": "Energy",
"roles": [
"Home_Owner"
],
"token": "8XXX8X888-XXXX8XXXXX8XXXXXXXXXXXXX_X8X8X8XXXXXXXXXXXXXXX8XX88XX_XXX8XXXXXX8XXXXXXXXXXX==",
"provider": "Basic",
"loginTime": "2024-01-02T17:36:36.205543924-08:00"
} We could switch to using that as the Bearer token instead of the AuthCookie and UserRecord tokens in pypowerwall. I wonder if anyone who has 23.44.0 could try this: import requests
from requests.packages.urllib3.exceptions import InsecureRequestWarning
requests.packages.urllib3.disable_warnings(InsecureRequestWarning)
# Replace with your Powerwall gateway address and login details
PASSWORD = "YourPassword"
HOST = "X.X.X.X"
EMAIL = "[email protected]"
TIMEZONE = "America/Los_Angeles"
def get_token(host, password, email, timezone):
# Login and create a new session
print("Attempting to login to Powerwall at %s" % host)
url = "https://%s/api/login/Basic" % host
pload = {"username":"customer","password":password,
"email":email,"clientInfo":{"timezone":timezone}}
try:
r = requests.post(url,data = pload, verify=False)
#print('login - %s' % r.text)
except:
print("Unable to connect to Powerwall")
return None
if r.status_code == 200:
# Return the response
data = r.json()
if "token" in data:
return data['token']
else:
print("Unable to find token in response")
return None
else:
# Handle errors
print(f"Error: {r.status_code}, {r.text}")
return None
def get_api(host, endpoint, token, binary=False):
# Get the API data
url = "https://%s/%s" % (host, endpoint)
print("Attempting to get data from Powerwall at %s" % url)
headers = {
"Authorization": "Bearer %s" % token,
}
try:
r = requests.get(url, headers=headers, verify=False)
except:
print("Unable to connect to Powerwall")
return None
if r.status_code == 200:
# Return the response
if binary:
return r.content
return r.json()
else:
# Handle errors
print(f"Error: {r.status_code}, {r.text}")
return None
token = get_token(HOST, PASSWORD, EMAIL, TIMEZONE)
if token:
# Some API Tests
for endpoint in ["api/meters/aggregates", "api/system_status/soe"]:
data = get_api(HOST, endpoint, token)
if data:
print("Data from %s:" % endpoint)
print(data)
else:
print("ERROR Unable to get %s:" % endpoint)
print("\n")
# Vitals API Test
endpoint = "api/devices/vitals"
data = get_api(HOST, endpoint, token, binary=True)
if data:
print("Raw binary vitals data from %s:" % endpoint)
print(data)
else:
print("ERROR Unable to get %s:" % endpoint)
# End of file Now, if that works. We can switch to this method (possibly as an option). The logic inside pypowerwall watches for 403 and does a session refresh (would get a new token). It would extend to using the Bearer. The code above works for me, but I'm still on Powerwall firmware 23.36.3 which still also allows access to /vitals through the AuthCookie so I don't know if the above would work for 23.44.0. |
@jasonacox I am on 23.44.0 and your code works for the APIs |
Thanks @FabienLavocat - I was worried about that, but it was worth a shot. I also don't think this will help the Powerwall 3 owners as that system doesn't seem to even allow a customer login. I added the v0.7.4 - Bearer Token AuthpyPowerwall Updates
import pypowerwall
pw = pypowerwall.Powerwall(HOST, PASSWORD, EMAIL, TIMEZONE, authmode="token") Proxy
|
Since firmware version 23.44.0 has eliminated |
🔥 CRITICAL Upgrade - Please take a moment and upgrade your installation of pypowerwall if you using it for your own scripts. The latest release includes the critical patch I mention above that fixes 404 HTTP status code handling for API calls. Older versions of pypowerwall will cause a repeating loop of login attempts eventually resulting in rate limiting and failure to get any metrics. NOTE: IF YOU HAVE FIRMWARE 23.44.0 YOU ARE IMPACTED AND SHOULD UPGRADE AS SOON AS POSSIBLE. pip install --upgrade pypowerwall Verify version 0.7.6 or greater:
🟢 pyPowerwall [0.7.6] Note: Users of pypowerwall proxy docker container should upgrade to the latest as well: An update is being prepared for Powerwall-Dashboard users. |
I like to begin by saying thank you for everyone's time, energy, and efforts toward this project; its been phenomenal to learn and use!
At 11:38pm last night I noticed that the pypowerwall was having authentication issues, I had to use the forget password function to reset the gateway password. Once I restarted everything I noticed that pypowerwall was no longer getting vitals and that the firmware version seems to be new.
output:
generated by:
The text was updated successfully, but these errors were encountered: