Notifications
You must be signed in to change notification settings - Fork 22
/
DEBUG
133 lines (98 loc) · 2.76 KB
/
DEBUG
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
unkown1:
--------
03 00 - Messwert (value)
07 00 - Parameter einstellbar
08 00 - Parameter einstellbar digital
11 00 - Digitaler Ausgang
12 00 - Analoger Ausgang
13 00 - Digitaler Eingang
18 00 -
19 00 -
0a 00 - Parameter einstellbar Tageszeit in Minuten von 00:00
-----------------------------------------
Menüstruktur
-----------------------------------------
1. Ebene
-----------------------------------------
Anlage
Heizen
Puffer
Kessel
Pellets
Zirku. Pumpe
Hand
Anlage
2. Ebene
-----------------------------------------
Anlage
-----------
Einstellen
Aktuelle Werte
Fehler
Fühler und Pumpen
Display Bedienrechte
Display Zuweisungen
Grundbild- Parameter
Betriebsart im Automatikbetrieb
Sprache - Language - Langue - Lingua - Jezik
Aktuelles Datum
Aktuelle Zeit
Standardeinstellungen übernehmen (Alle Werte werden zurückgesetzt!)
Aktuelle Bedienebene
Anlagenart
Heizen
-----------
Heizkreis 01
Heizkreis 02
Aufheiz Programm
Allg. Einst
-----------------------------------------
Unbekannte Kommandos
-----------------------------------------
## 0x33
-----------------------------------------
## 0x34
-----------------------------------------
## 0x35
-----------------------------------------
14:29:04,377 -> 02 FD 00 01 35 5D ....5]
14:29:04,386 <- 02 FD 00 FE 14 35 01 00 00 B0 00 00 02 00 00 0A 00 02 00 00 14 00 05 00 00 00 95 .....5.....................
## 0x36
-----------------------------------------
14:30:08,601 -> 02 FD 00 01 36 58 ....6X
14:30:08,610 <- 02 FD 00 FE 14 35 01 00 01 6D 00 00 3C 02 00 58 00 01 00 3C 00 0A 00 00 00 2F .....5...m..<..X...<...../
## 0x56
-----------------------------------------
14:31:34,241 -> 02 FD 00 01 56 F8 ....V.
14:31:34,252 <- 02 FD 00 23 56 01 00 92 C9 01 32 27 0A 0F 0B 0A 53 74 65 75 65 72 75 6E 67 20 6E 65 75 20 67 65 73 74 61 72 74 65 74 B3 ...#V.....2'....Steuerung neu gestartet.
## 0x57
-----------------------------------------
## 0x5B
-----------------------------------------
bytes to decode: 02, 2B, FE
## values:
<- 02 FD 00 1F 31 01 00 0A 00 02 00 01 25 00 03 52 65 73 74 73 61 75 65 72 73 74 6F 66 66 67 65 68 61 6C 74 00 4C ....1.......%..Restsauerstoffgehalt.L
38) 0x0003 10 '%' (0002) 'Restsauerstoffgehalt'
Header:
02 FD 00 1F 31
-> 2 byte "ID"
-> 2 byte "size"
-> 1 byte "command"
01
-> 1 byte "more to get"
00 0A
-> 2 byte "factor"
00 02
-> 2 byte "unknown"
00 01
-> 2 byte "unit" as text (byte 11,12)
25 00
-> 2 byte "address"
03 52 65 73 74 73 61 75 65 72 73 74 6F 66 66 67 65 68 61 6C 74
-> size-sizeCrc-1 bytes (Rest) "description"
00
-> 1 byte "termination byte"
4C
-> 1 byte "crc"
51) 0x0115 1 '' (0001) 'Tagesertrag [kWh]'
02 FD 00 1C 31 01 00 01 00 01 00 20 01 15 54 61 67 65 73 65 72 74 72 61 67 20 5B 6B 57 68 5D 00 4A ....1...... ..Tagesertrag [kWh].J