Hello @Dites33! I'm using the Z-Wave JS UI add-on for HA version: 3.13.1. I included the device through the Z-Wave integration in System > Devices (not through the Z-Wave JS UI add-on): I did it over a year ago, so the versions were different, but it worked without any issues then. I couldn't only establish a secure connection, but it happens among different devices. Maybe my gate is just too far from the controller (IDK exactly what may cause the problem). Here are the entities I can access in HA through the integration: I'm not sure if it helps... By no buttons are working do you mean that you do have them on the UI but the gate doesn't react or that they aren't available as HA entities at all? |
OK, that looks the same as in my case. Have you looked at the connections graph in Z-Wave UI? Check the edge colors between the nodes that join your gate controller with the Z-Wave controllers. Are all of them green or yellow, or are there any red ones, making the route unstable? Oh, there is one more thing that comes to my mind. There are two drop-down menus created by the integration:
Local protection state in Fibaro devices blocks physical buttons so when you press them, there is no reaction. RF protection, on the other hand, is an option that prevents controlling the device remotely, by Z-Wave commands. If that one is set to NoControl, then any control commands sent to the gate will be ignored. Please check these two and let me know if any of them was the case, @Dites33. Update: I'd also open the cover of the gate control unit and press the S button on the IBT4ZWAVE module. Just to check if there is a correct connection between the module and the control unit. Of course, make sure that the Local protection state option is not set to NoOperationPossible ;). |
I'm not sure if this is related or not but I noticed that after one of the latest updates, that my ZEN53 had stopped responding to open and close commands. I couldn't figure out why my chicken coop door hadn't been closing at night (or opening when I'd manually close it) and I noticed that the open and close buttons were not responding. Connection has been fine and this had been working, automated, for a few months until recently. I can, however, set the door to 100% and 0% to get it to open and close, which I found to be kind of odd. I just updated to again today and it seems to be back to somewhat working but it takes a while to update and there seems to be a delay with sending the command and the device responding. I don't see any connection issues with the device. |