You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
thanks for putting together a great resource for novices to genomics data analysis!
I would suggest changing the wording in the subsection "Align reads to reference genome". Currently it reads: "We will use the BWA-MEM algorithm, which is the latest and is generally recommended for high-quality queries as it is faster and more accurate."
I would change the focus to enabling learners to make an informed choice based on their sequencing read types and use case, instead of saying BWA-MEM is the latest, faster and more accurate (than what?). For example, minimap2 is much faster than BWA-MEM and claims to be more accurate. However, minimap2 is not suited to spliced alignment.
I would say something like this instead: "We will use the BWA-MEM algorithm, which is suited well to aligning accurate short-read transcriptomic Illumina data to genomic sequences. Alternatively, aligners such as minimap2 are well-suited for aligning noisy long-read data or short-read genomic Illumina data. The appropriate choice of aligner depending on the sequencing read types is crucial for down-stream high-quality genomic data analysis and some time should be spent choosing the best tool for the job."
Thanks,
Jana
The text was updated successfully, but these errors were encountered:
Hi,
thanks for putting together a great resource for novices to genomics data analysis!
I would suggest changing the wording in the subsection "Align reads to reference genome". Currently it reads: "We will use the BWA-MEM algorithm, which is the latest and is generally recommended for high-quality queries as it is faster and more accurate."
I would change the focus to enabling learners to make an informed choice based on their sequencing read types and use case, instead of saying BWA-MEM is the latest, faster and more accurate (than what?). For example, minimap2 is much faster than BWA-MEM and claims to be more accurate. However, minimap2 is not suited to spliced alignment.
I would say something like this instead: "We will use the BWA-MEM algorithm, which is suited well to aligning accurate short-read transcriptomic Illumina data to genomic sequences. Alternatively, aligners such as minimap2 are well-suited for aligning noisy long-read data or short-read genomic Illumina data. The appropriate choice of aligner depending on the sequencing read types is crucial for down-stream high-quality genomic data analysis and some time should be spent choosing the best tool for the job."
Thanks,
Jana
The text was updated successfully, but these errors were encountered: