active_cooling_on |
Active cooling |
R |
|
active_cooling_runtime_h |
Runtime active cooling |
R/W |
|
alarm_indication_on |
Alarm |
R |
|
aux1_heating_on |
Auxilliary 1 |
R |
|
aux2_heating_on |
Auxilliary 2 |
R |
|
boiler_3kw_on |
Aux. heater 3 kW |
R |
|
boiler_3kw_runtime_h |
Runtime 3 kW |
R/W |
|
boiler_6kw_on |
Aux. heater 6 kW |
R |
|
boiler_6kw_on_runtime_h |
Runtime 6 kW |
R/W |
|
boiler_sensor_alm |
Alarm hotw. t-sensor |
R |
|
boiler_sensor_offset_t |
Calibration hotwater sensor |
R/W |
|
boiler_t |
Hotwater temp. |
R |
|
brine_flow_alm |
Alarm low flow brine |
R |
|
brine_in_sensor_offset_t |
Calibration brine out sensor |
R/W |
|
brine_in_t |
Brine in temp. |
R |
|
brine_min_t |
Brinetemp., min limit (-15=OFFV) |
R/W |
|
brine_out_sensor_offset_t |
Calibration brine in sensor |
R/W |
|
brine_out_t |
Brine out temp. |
R |
|
brine_pump_on |
Brinepump |
R |
|
brine_pump_speed |
Brinepump speed |
R |
|
brine_run_in_t |
Brine run-in duration |
R/W |
|
brine_runout_t |
Brine run-out duration |
R/W |
|
brine_temperature_alm |
Alarm low temp. brine |
R |
|
compressor_on |
Compressor |
R |
|
compressor_runtime_h |
Runtime compressor |
R/W |
|
cooling_t |
Cooling temp. |
R |
|
cooling_target_t |
Cooling, target |
R/W |
|
current_consumed_a |
Electrical Current |
R |
|
current_consumption_max_a |
Electrical current, max limit |
R/W |
|
defrost_time_m |
Defrost |
R |
|
demand1 |
DEMAND1 |
R |
|
demand2 |
DEMAND2 |
R |
|
elect_boiler_steps_max |
Max Electric steps |
R/W |
|
factory_reset_req |
Reset to Factory settings |
R/W |
|
graph_display_offset |
GrafCounterOffSet |
R/W |
|
heating_stop_t |
Heatstop |
R/W |
|
heatingsystem_type |
Heating system type 0=VL 4=D |
R/W |
|
heatpump_runtime_m |
Heatpump operating time |
R/W |
|
hgw_water_t |
Hotw. supplyline temp. |
R |
|
highpressure_alm |
Alarm highpr.pressostate |
R |
|
hotwater_runtime_h |
Runtime hotwater production |
R/W |
|
hotwater_runtime_m |
Hotwater operating time |
R/W |
|
hotwater_start_t |
Hotwater starttemp. |
R/W |
|
hotwater_stop_t |
Hotwater stop temp. |
R/W |
|
hotwaterproduction_on |
Hotwater production. |
R |
|
indoor_dec_t |
Indoor temp., decimal |
R |
|
indoor_requested_t |
Indoor target temp. |
R/W |
|
indoor_sensor_alm |
Alarm indoor t-sensor |
R |
|
indoor_t |
Indoor temp. |
R |
|
indoor_target_dec_t |
Indoor target temp., decimal |
R |
|
indoor_target_t |
Indoor target temp. |
R |
|
integral1 |
Integral (A1) |
R |
|
integral1_a_limit |
Integral limit A1 |
R/W |
|
integral1_a_limit |
Integral, reached A-limit |
R |
|
integral1_curve_0 |
Curve 0 |
R/W |
|
integral1_curve_max |
Curve max |
R/W |
|
integral1_curve_min |
Curve min |
R/W |
|
integral1_curve_n5 |
Curve -5 |
R/W |
|
integral1_curve_p5 |
Curve +5 |
R/W |
|
integral1_curve_slope |
Curve |
R/W |
|
integral1_hysteresis_t |
Hysteresis A1 |
R/W |
|
integral2_a_limit |
Integral limit A2 |
R/W |
|
integral2_curve_actual |
Curve 2, Actual |
R/W |
|
integral2_curve_max |
Curve 2 max |
R/W |
|
integral2_curve_min |
Curve 2 min |
R/W |
|
integral2_curve_slope |
Curve 2 |
R/W |
|
integral2_curve_target |
Curve 2, Target |
R/W |
|
integral2_hysteresis_t |
Hysteresis limit A2 |
R/W |
|
internal_logging_t |
Logging time |
R/W |
|
language |
Language |
R/W |
|
legionella_interval_d |
Legionella interval |
R/W |
|
legionella_run_length_h |
Legionella peak heating duration |
R/W |
|
legionella_run_on |
Legionella peak heating enable |
R/W |
|
legionella_stop_t |
Legionella stop temp. |
R/W |
|
lowpressure_alm |
Alarm lowpr.pressostate |
R |
|
main_mode |
Mode |
R/W |
|
manual_test_mode_on |
Manual test mode |
R/W |
|
motorbreaker_alm |
Alarm motorcircuit breaker |
R |
|
msd1_d |
DACT_MSD1 |
R/W |
|
msd1_d |
DPAS_MSD1 |
R/W |
|
msd1_d |
DTS2_MSD1 |
R/W |
|
msd1_dtp |
DTS_MSD1 |
R/W |
|
msd1_dvp |
DVP_MSD1 |
R/W |
|
msd1_dvv |
DVV_MSD1 |
R/W |
|
opt_2_installed |
TILL2 |
R/W |
|
opt_4_installed |
TILL4 |
R/W |
|
opt_5_installed |
TILL5 |
R/W |
|
opt_6_installed |
TILL6 |
R/W |
|
opt_flowguard_installed |
Add-on flow guard |
R/W |
|
opt_hgw_installed |
Add-on HGW |
R/W |
|
opt_optimum_installed |
Add-on Optimum |
R/W |
|
opt_phasemeassure_installed |
Add-on phase order measurement |
R/W |
|
outdoor_sensor_alm |
Alarm outdoor t-sensor |
R |
|
outdoor_sensor_offset_t |
Calibration outdoor sensor |
R/W |
|
outdoor_stop_t |
Outdoor stop temp. (20=-20C) |
R/W |
|
outdoor_t |
Outdoor temp. |
R |
|
overheating_alm |
Alarm overheating |
R |
|
passive_cooling_on |
Passive cooling |
R |
|
passive_cooling_runtime_h |
Runtime passive cooling |
R/W |
|
phase_order_alm |
Alarm incorrect 3-phase order |
R |
|
pressure_pipe_limit_t |
Pressurepipe, temp. limit |
R/W |
|
pressurepipe_t |
Pressurepipe temp. |
R |
|
pwm_out_period |
PWM Out |
R |
|
reduction_t |
Temp. reduction |
R/W |
|
returnline_max_t |
Returnline temp., max limit |
R/W |
|
returnline_sensor_alm |
Alarm returnline t-sensor |
R |
|
returnline_sensor_offset_t |
Calibration returnline sensor |
R/W |
|
returnline_t |
Returnline temp. |
R |
|
room_factor |
Room factor |
R/W |
|
runtime_counters_reset_req |
Reset runtime counters |
R/W |
|
shunt1_n |
Shunt - |
R |
|
shunt1_p |
Shunt + |
R |
|
shunt2_n |
Shuntgroup - |
R |
|
shunt2_p |
Shuntgroup + |
R |
|
shunt_cooling_n |
Shunt cooling - |
R |
|
shunt_cooling_p |
Shunt cooling + |
R |
|
shunt_time_s |
Shunt time |
R/W |
|
start_interval_min_m |
Minimum start interval |
R/W |
|
status3_m |
STATUS3 |
R |
|
status7 |
DT_LARMOFF |
R/W |
|
status8 |
SERVFAS |
R/W |
|
supply_pump_on |
Flowlinepump |
R |
|
supply_pump_speed |
Flowlinepump speed |
R |
|
supply_shunt_t |
Supplyline temp., shunt |
R |
|
supplyline_sensor_alm |
Alarm supplyline t-sensor |
R |
|
supplyline_sensor_offset_t |
Calibration supplyline sensor |
R/W |
|
supplyline_shunt_target_t |
Supplyline target temp., shunt |
R |
|
supplyline_t |
Supplyline temp. |
R |
|
supplyline_target_t |
Supplyline target temp. |
R |
|
sw_version |
Program version |
R |
|
time_to_start_min_m |
Minimum time to start |
R |
|