ISerialComEventListener and CTS change #43

Open
akuhtz opened this issue Nov 29, 2020 · 6 comments
Open

ISerialComEventListener and CTS change #43

akuhtz opened this issue Nov 29, 2020 · 6 comments

Comments

@akuhtz
Copy link

akuhtz commented Nov 29, 2020

Hello Rishi,

The ISerialComEventListener is only called once if linestatus CTS changes from 1 to 0 but not if line status changes from 0 to 1.
I'm testing on Windows 10 64-bit and I use FLOWCONTROL.RTS_CTS.

@akuhtz akuhtz closed this as completed Nov 29, 2020
@akuhtz
Copy link
Author

akuhtz commented Nov 29, 2020

I did a wrong evaluation of the event data. Sorry for the noise.

@akuhtz akuhtz reopened this Dec 1, 2020
@akuhtz
Copy link
Author

akuhtz commented Dec 1, 2020

Hello Rishi,
I reopen this issue after testing with Test15 under Windows 10 64-bit.
It does not work as expected.

When using FLOWCONTROL.RTS_CTS and calling

scm.setRTS(handle1, false);

it throws this exception:

com.serialpundit.core.SerialComException: The parameter is incorrect.
	at com.serialpundit.serial.internal.SerialComPortJNIBridge.setRTS(Native Method)
	at com.serialpundit.serial.SerialComManager.setRTS(SerialComManager.java:1505)

However it does not throw an exception if FLOWCONTROL.NONE is used.

Then I changed Test15to get the line status after toggle DTR and RTS (after sleep 1000). The output shows that a change of DTR from true to false triggers the EventLooper thread, but a change from false to true does not trigger the EventLooper thread.

14:59:54.997 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [Initial] Fetched current line status, CTS: 1, DSR: 0, DCD: 0
14:59:54.997 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventCTS : 1
14:59:55.003 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventDSR : 0
14:59:57.005 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
14:59:58.005 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [DTR: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
14:59:58.005 [INFO] org.bidib.jbidibc.scm.Test15 [main] - Loop: 20
14:59:58.006 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventCTS : 0
14:59:58.006 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventDSR : 0
14:59:59.007 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: true] Fetched current line status, CTS: 1, DSR: 0, DCD: 0
15:00:00.008 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [DTR: true] Fetched current line status, CTS: 1, DSR: 0, DCD: 0
15:00:01.008 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
15:00:02.008 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [DTR: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
15:00:02.008 [INFO] org.bidib.jbidibc.scm.Test15 [main] - Loop: 19
15:00:02.008 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventCTS : 0
15:00:02.008 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventDSR : 0
15:00:03.009 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: true] Fetched current line status, CTS: 1, DSR: 0, DCD: 0
15:00:04.009 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [DTR: true] Fetched current line status, CTS: 1, DSR: 0, DCD: 0
15:00:05.010 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
15:00:06.010 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [DTR: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
15:00:06.010 [INFO] org.bidib.jbidibc.scm.Test15 [main] - Loop: 18
15:00:06.010 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventCTS : 0
15:00:06.010 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventDSR : 0
15:00:07.010 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: true] Fetched current line status, CTS: 1, DSR: 0, DCD: 0
15:00:08.011 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [DTR: true] Fetched current line status, CTS: 1, DSR: 0, DCD: 0
15:00:09.011 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
15:00:10.012 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [DTR: false] Fetched current line status, CTS: 0, DSR: 0, DCD: 0
15:00:10.012 [INFO] org.bidib.jbidibc.scm.Test15 [main] - Loop: 17
15:00:10.012 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventCTS : 0
15:00:10.013 [INFO] org.bidib.jbidibc.scm.EventListener [SerialPundit EventLooper for handle 1612 and port COM10] - eventDSR : 0
15:00:11.012 [INFO] org.bidib.jbidibc.scm.Test15 [main] - [RTS: true] Fetched current line status, CTS: 1, DSR: 0, DCD: 0

@RishiGupta12
Copy link
Owner

RishiGupta12 commented Dec 3, 2020 via email

@akuhtz
Copy link
Author

akuhtz commented Dec 3, 2020

Ok, now I understand: The FLOWCONTROL.RTS_CTS sets the fRtsControl to RTS_CONTROL_HANDSHAKE while FLOWCONTROL.NONE allows to use setRTS(...) manually.

I changed to FLOWCONTROL.NONE but the change of the status of the CTS line is still only signalled as event if CTS value changed from 0 to 1.

@RishiGupta12
Copy link
Owner

RishiGupta12 commented Dec 5, 2020 via email

@akuhtz
Copy link
Author

akuhtz commented Dec 7, 2020

From my understanding every change of the line status should result in an event. There are some devices that change the line status to signal the application that no more data must be sent because e.g. the input buffer is full. After some time when the device has processed the input buffer is changes the line status to signal that more data can be sent.

I tested with hterm (http://www.der-hammer.info/pages/terminal.html) and a FTDI board (YP-05) where I connected the RTS and CTS pins with a jumper cable. Then connect in hterm and press the RTS button in the Input control area. This makes the CTS led in hterm change to light green. Press again on CTS makes the led turn off.

Then I tested with RXTX (https://github.com/NeuronRobotics/nrjavaserial) and it signals the change of line status, too, if I plug off the jumper cable from the RTS pin and put it back again.

I still have to test it with a simple C++ application.