Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

define runner cannot run properly if the coord file only contains one atom. #38

Open
WentongZhou opened this issue Apr 24, 2023 · 1 comment

Comments

@WentongZhou
Copy link

WentongZhou commented Apr 24, 2023

I just ran the codes below to generate control files. Most of them work perfectly, but if the coord only contains one atom, it reports errors.
os.system(f'x2t coord.xyz > coord')
dp_b = get_define_template(ridft_path)
dp_b['charge'] = 1
dr_b = DefineRunner(parameters=dp_b)
dr_b.run_full()

the error is
turbomoleio.input.define.DefineExpectError: Expect could not find the pattern: ['ENTER THE MOLECULAR CHARGE*']. The job was alive.

the coord file is as below:
$coord
-8.60844330793820 7.57371620497213 -8.58652437452286 li
$user-defined bonds
$end

@davidwaroquiers
Copy link
Member

Hello @WentongZhou

Thank you for opening this issue. Indeed, the DefineRunner currently does not work for just one atom. We currently don't have the resources to adapt it so that it works with one atom but if'd like to contribute and make a PR, we'd be happy to review it.

Best

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment