English | 简体中文
Spiderpool introduces the SpiderMultusConfig CR to automate the management of Multus NetworkAttachmentDefinition CR and extend the capabilities of Multus CNI configurations.
Multus is a CNI plugin project that enables Pods to access multiple network interfaces by leveraging third-party CNI plugins. While Multus allows management of CNI configurations through CRDs, manually writing JSON-formatted CNI configuration strings can lead to error:
-
Human errors in writing JSON format may cause troubleshooting difficulties and Pod startup failures.
-
There are numerous CNIs with various configuration options, making it difficult to remember them all, and users often need to refer to documentation, resulting in a poor user experience.
To address these issues, SpiderMultusConfig automatically generates the Multus CR based on its spec
. It offers several features:
-
In case of accidental deletion of a Multus CR, SpiderMultusConfig will automatically recreate it, improving operational fault tolerance.
-
Support for various CNIs, such as Macvlan, IPvlan, Ovs, and SR-IOV.
-
The annotation
multus.spidernet.io/cr-name
allows users to define a custom name for Multus CR. -
The annotation
multus.spidernet.io/cni-version
enables specifying a specific CNI version. -
A robust webhook mechanism is involved to proactively detect and prevent human errors, reducing troubleshooting efforts.
-
Spiderpool's CNI plugins, including ifacer and coordinator are integrated, enhancing the overall configuration experience.
It is important to note that when creating a SpiderMultusConfig CR with the same name as an existing Multus CR, the Multus CR instance will be managed by SpiderMultusConfig, and its configuration will be overwritten. To avoid overwriting existing Multus CR instances, it is recommended to either refrain from creating SpiderMultusConfig CR instances with the same name or specify a different name for the generated Multus CR using the
multus.spidernet.io/cr-name
annotation in the SpiderMultusConfig CR.
-
A ready Kubernetes cluster.
-
Helm has been installed.
Refer to Installation to install Spiderpool.
SpiderMultusConfig CR supports various types of CNIs. The following sections explain how to create these configurations.
Here is an example of creating Macvlan SpiderMultusConfig configurations:
- master:
ens192
is used as the master interface parameter.
MACVLAN_MASTER_INTERFACE="ens192"
MACVLAN_MULTUS_NAME="macvlan-$MACVLAN_MASTER_INTERFACE"
cat <<EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: ${MACVLAN_MULTUS_NAME}
namespace: kube-system
spec:
cniType: macvlan
enableCoordinator: true
macvlan:
master:
- ${MACVLAN_MASTER_INTERFACE}
EOF
Create the Macvlan SpiderMultusConfig using the provided configuration. This will automatically generate the corresponding Multus NetworkAttachmentDefinition CR and manage its lifecycle.
~# kubectl get spidermultusconfigs.spiderpool.spidernet.io -n kube-system
NAME AGE
macvlan-ens192 26m
~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system macvlan-ens192 -oyaml
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
annotations:
kubectl.kubernetes.io/last-applied-configuration: |
{"apiVersion":"spiderpool.spidernet.io/v2beta1","kind":"SpiderMultusConfig","metadata":{"annotations":{},"name":"macvlan-ens192","namespace":"kube-system"},"spec":{"cniType":"macvlan","enableCoordinator":true,"macvlan":{"master":["ens192"]}}}
creationTimestamp: "2023-09-11T09:02:43Z"
generation: 1
name: macvlan-ens192
namespace: kube-system
ownerReferences:
- apiVersion: spiderpool.spidernet.io/v2beta1
blockOwnerDeletion: true
controller: true
kind: SpiderMultusConfig
name: macvlan-ens192
uid: 94bbd704-ff9d-4318-8356-f4ae59856228
resourceVersion: "5288986"
uid: d8fa48c8-0877-440d-9b66-88edd7af5808
spec:
config: '{"cniVersion":"0.3.1","name":"macvlan-ens192","plugins":[{"type":"macvlan","master":"ens192","mode":"bridge","ipam":{"type":"spiderpool"}},{"type":"coordinator"}]}'
Here is an example of creating IPvlan SpiderMultusConfig configurations:
-
master:
ens192
is used as the master interface parameter. -
When using IPVlan as the cluster's CNI, the kernel version must be higher than 4.2.
-
A single main interface cannot be used by both Macvlan and IPvlan simultaneously.
IPVLAN_MASTER_INTERFACE="ens192"
IPVLAN_MULTUS_NAME="ipvlan-$IPVLAN_MASTER_INTERFACE"
cat <<EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: ${IPVLAN_MULTUS_NAME}
namespace: kube-system
spec:
cniType: ipvlan
enableCoordinator: true
ipvlan:
master:
- ${IPVLAN_MASTER_INTERFACE}
EOF
Create the IPvlan SpiderMultusConfig using the provided configuration. This will automatically generate the corresponding Multus NetworkAttachmentDefinition CR and manage its lifecycle.
~# kubectl get spidermultusconfigs.spiderpool.spidernet.io -n kube-system
NAME AGE
ipvlan-ens192 12s
~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system ipvlan-ens192 -oyaml
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
annotations:
kubectl.kubernetes.io/last-applied-configuration: |
{"apiVersion":"spiderpool.spidernet.io/v2beta1","kind":"SpiderMultusConfig","metadata":{"annotations":{},"name":"ipvlan-ens192","namespace":"kube-system"},"spec":{"cniType":"ipvlan","enableCoordinator":true,"ipvlan":{"master":["ens192"]}}}
creationTimestamp: "2023-09-14T10:21:26Z"
generation: 1
name: ipvlan-ens192
namespace: kube-system
ownerReferences:
- apiVersion: spiderpool.spidernet.io/v2beta1
blockOwnerDeletion: true
controller: true
kind: SpiderMultusConfig
name: ipvlan-ens192
uid: accac945-9296-440e-abe8-6f6938fdb895
resourceVersion: "5950921"
uid: e24afb76-e552-4f73-bab0-8fd345605c2a
spec:
config: '{"cniVersion":"0.3.1","name":"ipvlan-ens192","plugins":[{"type":"ipvlan","master":"ens192","ipam":{"type":"spiderpool"}},{"type":"coordinator"}]}'
Here is an example of creating Sriov SpiderMultusConfig configuration:
- Basic example
cat <<EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: sriov-demo
namespace: kube-system
spec:
cniType: sriov
enableCoordinator: true
sriov:
resourceName: spidernet.io/sriov_netdeivce
vlanID: 100
EOF
After creation, check the corresponding Multus NetworkAttachmentDefinition CR:
~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system sriov-demo -o yaml
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
name: sriov-demo
namespace: kube-system
annotations:
k8s.v1.cni.cncf.io/resourceName: spidernet.io/sriov_netdeivce
ownerReferences:
- apiVersion: spiderpool.spidernet.io/v2beta1
blockOwnerDeletion: true
controller: true
kind: SpiderMultusConfig
name: sriov-demo
uid: b08ce054-1ae8-414a-b37c-7fd6988b1b8e
resourceVersion: "153002297"
uid: 4413e1fa-ce15-4acf-bce8-48b5028c0568
spec:
config: '{"cniVersion":"0.3.1","name":"sriov-demo","plugins":[{"vlan":100,"type":"sriov","ipam":{"type":"spiderpool"}},{"type":"coordinator"}]}'
For more information, refer to sriov-cni usage
- Enable RDMA feature
cat <<EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: sriov-rdma
namespace: kube-system
spec:
cniType: sriov
enableCoordinator: true
sriov:
enableRdma: true
resourceName: spidernet.io/sriov_netdeivce
vlanID: 100
EOF
After creation, check the corresponding Multus NetworkAttachmentDefinition CR:
~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system sriov-rdma -o yaml
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
name: sriov-rdma
namespace: kube-system
annotations:
k8s.v1.cni.cncf.io/resourceName: spidernet.io/sriov_netdeivce
ownerReferences:
- apiVersion: spiderpool.spidernet.io/v2beta1
blockOwnerDeletion: true
controller: true
kind: SpiderMultusConfig
name: sriov-rdma
uid: b08ce054-1ae8-414a-b37c-7fd6988b1b8e
resourceVersion: "153002297"
uid: 4413e1fa-ce15-4acf-bce8-48b5028c0568
spec:
config: '{"cniVersion":"0.3.1","name":"sriov-rdma","plugins":[{"vlan":100,"type":"sriov","ipam":{"type":"spiderpool"}},{"type":"rdma"},{"type":"coordinator"}]}'
- Configure Sriov-CNI Network Bandwidth
We can configure the network bandwidth of Sriov through SpiderMultusConfig:
cat <<EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: sriov-bandwidth
namespace: kube-system
spec:
cniType: sriov
enableCoordinator: true
sriov:
resourceName: spidernet.io/sriov_netdeivce
vlanID: 100
minTxRateMbps: 100
MaxTxRateMbps: 1000
EOF
minTxRateMbps and MaxTxRateMbps configure the transmission bandwidth range for pods created with this configuration: [100,1000].
After creation, check the corresponding Multus NetworkAttachmentDefinition CR:
~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system sriov-rdma -o yaml
apiVersion: k8s.cni.cncf.io/v1
kind: NetworkAttachmentDefinition
metadata:
name: sriov-bandwidth
namespace: kube-system
annotations:
k8s.v1.cni.cncf.io/resourceName: spidernet.io/sriov_netdeivce
ownerReferences:
- apiVersion: spiderpool.spidernet.io/v2beta1
blockOwnerDeletion: true
controller: true
kind: SpiderMultusConfig
name: sriov-bandwidth
uid: b08ce054-1ae8-414a-b37c-7fd6988b1b8e
spec:
config: '{"cniVersion":"0.3.1","name":"sriov-bandwidth","plugins":[{"vlan":100,"type":"sriov","minTxRate": 100, "maxTxRate": 1000,"ipam":{"type":"spiderpool"}},{"type":"rdma"},{"type":"coordinator"}]}'
The Ifacer plug-in can help us automatically create a Bond NIC or VLAN NIC when creating a pod to undertake the pod's underlying network. For more information, refer to Ifacer.
If we need a VLAN sub-interface to take over the underlying network of the pod, and the interface has not yet been created on the node. We can inject the configuration of the vlanID in Spidermultusconfig
so that when the corresponding Multus NetworkAttachmentDefinition CR is generated, it will be injected The ifacer
plug-in will dynamically create a VLAN interface on the host when the pod is created,
which is used to undertake the pod's underlay network.
The following is an example of CNI as IPVlan, IPVLAN_MASTER_INTERFACE as ens192, and vlanID as 100.
~# IPVLAN_MASTER_INTERFACE="ens192"
~# IPVLAN_MULTUS_NAME="ipvlan-$IPVLAN_MASTER_INTERFACE"
~# cat <<EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: ipvlan-ens192-vlan100
namespace: kube-system
spec:
cniType: ipvlan
enableCoordinator: true
ipvlan:
master:
- ${IPVLAN_MASTER_INTERFACE}
vlanID: 100
EOF
When the Spidermultuconfig object is created, view the corresponding Multus network-attachment-definition object:
~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system macvlan-conf -o=jsonpath='{.spec.config}' | jq
{
"cniVersion": "0.3.1",
"name": "ipvlan-ens192-vlan100",
"plugins": [
{
"type": "ifacer",
"interfaces": [
"ens192"
],
"vlanID": 100
},
{
"type": "ipvlan",
"ipam": {
"type": "spiderpool"
},
"master": "ens192.100",
"mode": "bridge"
},
{
"type": "coordinator",
}
]
}
ifacer
is called first in the CNI chaining sequence. Depending on the configuration,ifacer
will create a sub-interface with a VLAN tag of 100 named ens192.100 based onens192
.main CNI: The value of the master field of IPVlan is:
ens192.100
, which is the VLAN sub-interface created by 'ifacer':ens192.100
.Note: The NIC created by
ifacer
is not persistent, and will be lost if the node is restarted or manually deleted. Restarting the pod is automatically added back.
Sometimes the network administrator has already created the VLAN sub-interface, and we don't need to use ifacer
to create the VLAN sub-interface. We can directly configure the master
field as: ens192.100
and not configure the VLAN ID, as follows:
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: macvlan-conf
namespace: kube-system
spec:
cniType: macvlan
macvlan:
master:
- ens192.100
ippools:
ipv4:
- vlan100
If we need a bond interface to take over the underlying network of the pod, and the bond interface has not yet been created on the node. We can configure multiple master interfaces in
Spidermultusconfig so that the corresponding Multus NetworkAttachmentDefinition CR is generated and injected The ifacer'
plug-in will dynamically create a bond interface on the host
when the pod is created, which is used to undertake the underlying network of the pod.
The following is an example of CNI as IPVlan, host interface ens192, and ens224 as slave to create a bond interface:
~# cat << EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: ipvlan-conf
namespace: kube-system
spec:
cniType: ipvlan
macvlan:
master:
- ens192
- ens224
bond:
name: bond0
mode: 1
options: ""
EOF
When the Spidermultuconfig object is created, view the corresponding Multus network-attachment-definition object:
~# kubectl get network-attachment-definitions.k8s.cni.cncf.io -n kube-system ipvlan-conf -o jsonpath='{.spec.config}' | jq
{
"cniVersion": "0.3.1",
"name": "ipvlan-conf",
"plugins": [
{
"type": "ifacer",
"interfaces": [
"ens192"
"ens224"
],
"bond": {
"name": "bond0",
"mode": 1
}
},
{
"type": "ipvlan",
"ipam": {
"type": "spiderpool"
},
"master": "bond0",
"mode": "bridge"
},
{
"type": "coordinator",
}
]
}
Configuration description:
ifacer
is called first in the CNI chaining sequence. Depending on the configuration,ifacer
will create a bond interface named 'bond0' based on ["ens192","ens224"] with mode 1 (active-backup).main CNI: The value of the master field of IPvlan is:
bond0
, bond0 takes over the network traffic of the pod.Create a Bond If you need a more advanced configuration, you can do so by configuring SpiderMultusConfig: macvlan-conf.spec.macvlan.bond.options. The input format is: "primary=ens160; arp_interval=1", use ";" for multiple parameters.
If we need to create a VLAN sub-interface based on the created BOND NIC: bond0, so that the VLAN sub-interface undertakes the underlying network of the pod, we can refer to the following configuration:
~# cat << EOF | kubectl apply -f -
apiVersion: spiderpool.spidernet.io/v2beta1
kind: SpiderMultusConfig
metadata:
name: ipvlan-conf
namespace: kube-system
spec:
cniType: ipvlan
macvlan:
master:
- ens192
- ens224
vlanID: 100
bond:
name: bond0
mode: 1
options: ""
EOF
When creating a pod with the above configuration,
ifacer
will create a bond NIC bond0 and a VLAN NIC bond0.100 on the host.
To create other types of CNI configurations, such OVS, refer to Ovs.
SpiderMultusConfig CR automates the management of Multus NetworkAttachmentDefinition CRs, improving the experience of creating configurations and reducing operational costs.