namelists have pottemp_equal_contemp=.true. causing SST problems #148

Closed
russfiedler opened this issue May 20, 2019 · 2 comments
Closed

Comments

@russfiedler
Copy link

Setting the conservative and potential temperatures to be the same is not a good thing. It doesn't matter so much in simulations with PT as the prognostic temperature but if you have CT as the temperature you may end up passing the wrong temperature to the coupler.

See also

mom-ocean/MOM5#284

aekiss added a commit to COSIMA/01deg_jra55_iaf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/01deg_jra55_ryf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/025deg_core2_nyf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/025deg_jra55_iaf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/025deg_jra55_ryf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/1deg_jra55_iaf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/1deg_jra55_ryf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/minimal_01deg_jra55_iaf that referenced this issue May 20, 2019
aekiss added a commit to COSIMA/minimal_01deg_jra55_ryf that referenced this issue May 20, 2019
@aekiss
Copy link
Contributor

aekiss commented Aug 12, 2019

I've removed pottemp_equal_contemp from input.nml so it defaults to false for all default configurations at 1, 0.25 and 0.1 deg (currently in ak-dev branch but will be merged into master).

Can this issue now be closed?

@aekiss
Copy link
Contributor

aekiss commented Aug 13, 2019

Screen Shot 2019-08-14 at Wed 14-8 8 57am

Just for reference, here's the difference between potential and conservative temperature at the sea surface from p 98 of the TEOS-10 manual.